Solvent Weld Glue female loose nut connections
Maximum pressure rating 1000kPa
1/4 turn on/off control manually operated
Body uPVC, Seal PTEE, O-Ring EDPM, Ball uPVC, Handle ABS
Ball Valve Installation Procedures
When joining union- end valves, never make the joint to the end connectors while they are attached to the valve body. Remove the union nuts and end connectors from the valve cartridge first. In order to prevent mishaps with the union nut, slide it over the pipe or nipple before making the joint to the end connector.
Use a spanner to tight the nuts of the valve. Valve nuts have to be tighten by hand onto the body and never used a metal tool. If the tightness is not good enough, then lubricate the threads with Vaseline grease or silicone oil to achieve the required tightness.
Socket-End Valves Caution: Do not allow primer or solvent cement to come in contact with the sealing face of the end connectors. When joining the fixed end of a single union valve, place the ball in the open position to allow for proper drying and to avoid primer or solvent cement contacting internal components of the valve.
80mm 3" PVC Ball Valve Double Union Pressure Solvent Weld Joint STBVDUS80 is a high pressure manually operated valve that is predominately used to manually change or to stop flow and is used in various applications for the plumbing, pool building and Irrigation industry.